READ ALL INSTRUCTIONS ENCLOSED BEFORE INSTALLATION.

Handling

Do Not drop or use an oxygen sensor that has been dropped as this may have caused shock damage to the ceramic element

Do Not use any compounds on or around the sensor unless labeled as oxygen sensor friendly products

Do Not use impact wrench or conventional socket type wrench to install sensor

Do Not allow sensor or lead wire to touch exhaust manifold or any other hot component

Do Not expose this product to water, oil, windshield cleaner, anticorrison oil, grase, terminal cleaner etc

Do Not use leaded fuels, silicone or metal based additives

Do Not store under high humidity conditions

 

Step 1:

Disconected the old oxygen sensor from vehicle harness using extra care not to damage connector, as it must be reused.

Step 2:

Remove old sensor from vehicle using an 02 sensor socket or 22mm wrench. Place the old and new oxygen sensor side by side on a flat surface, preparing to make an accurate cut of the lead wires. Cut the lead wires of the old sensor to a length that when the plug end is spliced to the new universal sensor, the overall length will be the same or slightly longer than the old sensor.

Important!!  Before making the cut, add 2" to 3" of additional length to the plug end to allow for the extra wire needed when making the staggered.

Step 3:

Stagger-cut wire leads stripping off approx. 1/4" of insulation from the end of each wire.

For the Step #4 and #5:

Please refer to the attached wire placement & colour coding diagrams in the installation instructions to determine proper wire matching of universal sensor leads to connector leads for each specific application (heater wires are not polarity dependant)

 

WARNING: DO NOT CONNECT TO YOUR SENSOR IF YOU CANNOT MATCH WIRE COLORS.

                   

                            

                       Type A         Type B       HONDA     GM          TITANIA

OE Heater        White    =     Black    =     Black   =    Brown    =    White

OE Heater         White   =     Black    =     Black   =    Brown    =    Red

OE Signal           Black   =     Blue      =     White   =    Purple    =    Black

OE Ground        Gray    =     White    =     Green   =    Tan    

 

Step 4:

A.- On universal sensors where heat-shrink tubes are already installed:   Insert just striped portion of wires into crimp terminals of new sensor and crimp terminals

B.- On universal sensors where heat-shrink tubes are not installed:  Insert just striped portion of wires into crimp type "butt" connectors (approx. 1/4") and crimp.

Step 5:

After all conections have been made, slip the  heat shrink tube over the crimped connections and heat the tube with an appropriate heat source until the conection is completely sealed, taking care not to over-heat or burn tubing.

Step 6:

Remove protector cap just prior to installation.                                                                               

A) Flanged applications-(where flange is not already installed on sensor) Install flange to exhaust manifold first, then sensro in flange(a copper gasket is bonded to the flange & no additional gasket is required)

B) Flanged applications-(where flange is already installed on sensor) It is important to use supplied gasket before installing sensor)

Step7:

If not already coated, apply (enclosed) anti-seize to oxygen sensor threads.

Step8:

Install sensor body ensuring lead wire is not twisted or bent.

Step9:

Install all sensors with gasket supplied & torque to proper specs as bellow:

M18 sensors- install finger tight then 1/2 - 1/3 turn with wrench / 02 sensor socket 35-45nm

M12 sensor- install finger tight then 3/4 - 1 turn with wrench / 02 sensor socket 18-23nm

Step 10:

Connect and route lead wire as oringinally installed.

Hope this guide helps you in making a purchase of sensor,

If you feel that this guide is helpful to you, please click "YES" button in the buyer poll section below.

THE JACP'S GARAGE.

THANK YOU!


Guide ID: 10000000003831767Guide created: 06/19/07 (updated 10/08/08)

 
Was this guide helpful? Report this guide

Ready to share your knowledge with others? Write a guide



Member Information

jacp37
jacp37( 2845Feedback score is 1000 to 4,999) Member is a PowerSeller
See all guides by this member
View items for sale by this memberVisit this seller's eBay Store!
Member has an eBay StoreThe Jacp's Garage

See member's items

 


eBay Pulse | eBay Reviews | eBay Stores | Half.com | Reseller Marketplace | Austria | France | Germany | Italy | Spain | United Kingdom | Popular Searches
Kijiji | PayPal | ProStores | Apartments for Rent | Shopping.com | Skype | Tickets


About eBay | Announcements | Security Center | eBay Toolbar | Policies | Government Relations | Site Map | Help
Copyright © 1995-2008 eBay Inc. All Rights Reserved. Designated trademarks and brands are the property of their respective owners. Use of this Web site constitutes acceptance of the eBay User Agreement and Privacy Policy.
eBay official time